Boiler Chemical
Ideal for hard water conditions. Chemworld is an All-in-One All-Polymer internal treatment product. Chemworld includes polymer for deposit control, alkalinity builder for maintaining the boiler alkalinity, and sulfite for removing oxygen from the boiler water.
Chemworld does not include neutralizing amine which, if required, should be fed in combination with this product to maintain condensate quality. Chemworld is typically used in systems with make-up water that has not been softened.
This product is ideal:
- For gradual removal of existing boiler scale. Install a softener before using. If you do not stop new scale from entering, the problem will never go away.
- Feedrates: to ppm should be sufficient when specified operating conditions are met.
- Maximum feedwater
hardness
View Details
is 5 ppm as CaCO3 for minimum recommended treatment concentration. - For those that want more details of control (but follow the directions below in order to keep it simple.) Keep
"P' Alkalinity
in the range of 300 to 600 ppm; sulfite
(SO3) residual 20 to 40 ppm , and Make-up 'M' Alk = 15 to 50 ppm as CaCO3. - For condensate returns > 60%.
- The easiest way to use this chemical is to monitor conductivity and sulfite.
How to use:
ChemWorld is an all-in-boiler chemical. They are designed to make boiler chemical feeding and testing easy.
- Download our
boiler testing logsheet
and use it as a reference. - Feed the chemical as far back into your steam boiler system (into the feed water tank, DA tank, or feed water line). This will ensure the metal as far back in the system is protected against corrosion.
- Keep a minimum of 20 ppm of sulfite residual (or use ASTM standards) on all active and idle boiler systems to reduce the risk of oxygen corrosion within your boiler. If you have excess product, it will raise your conductivity levels but will have no adverse effect on your boiler. You are just wasting chemical, water, and thermal energy within the water.
- If your boiler conductivity is too low, you are probably blowdown to much water or grossly overfeeding the chemical. Reduce blowdown and reduce chemical dosage and wait a few days. Allow the water to cycle up again within the boiler. Remember the purpose of your steam boiler system is to reuse water. Target a conductivity of 2,000 to 3,000 umhos (most steam boilers). For mid to large size steam boilers, we always recommend automation with a
LakeWood Conductivity Controller
. Using a Myron Meter
is an easy way to verify your conductivity of your controller and boiler water. - This chemical will add additional conductivity to your boiler water. Overfeeding will have no adverse effect to the boiler, but it will waste chemical and you will blowdown excess water. Conductivity is a measurement of dissolved solids, dissolved gases, and suspended solids.
- Add more product as needed based on sulfite residual in your boiler water, but remember to keep your conductivity in range or your sulfite reading will be irrelevant. Use a
Sulfite Test Kit
to verify your residual. - Monitor the boiler water
Hardness
as a reference. - This product needs to be added daily, bi-weekly, or weekly depending on how your systems operate. In theory, the more frequently you add it, the less you will use.
- The purpose of the chemical is to prevent corrosion and scale prevention. As long as you have any sulfite in the boiler water, it means you have no dissolved oxygen in the boiler water.
- If you have any other questions, please us at
[ protected]
. Remember to keep it simple. This is an easy boiler chemical to use as long as you get it into the system, you maintain proper conductivity levels within the boiler, you have a good operating softener, and you periodically check that sulfite is in the boiler. Do not over complicate it.
For new steam boiler startups, consider purchasing our Ideal for hard water conditions. Chemworld is an All-in-One All-Polymer internal treatment product. Chemworld includes polymer for deposit control, alkalinity builder for maintaining the boiler alkalinity, and sulfite for removing oxygen from the boiler water.Chemworld does not include neutralizing amine which, if required, should be fed in combination with this product to maintain condensate quality. Chemworld is typically used in systems with make-up water that has not been softened.This product is ideal:ChemWorld is an all-in-boiler chemical. They are designed to make boiler chemical feeding and testing easy.For new steam boiler startups, consider purchasing our Steam Boiler Startup Kit
ISO specifications. Lead time on production is
4 to 7 days
.
Free shipping transit time in business days as of May (After Production).Remember production time is 4 to 7 days. This map is transit time. You will receive your tracking number within a week after ordering.
This product is manufactured to order per. Lead time on production is
_______________________________________________________________________________________________________
Follow the information below and see how you can save thousands of dollars a year in energy costs.
Savings are based on 300 Tons Water Source Heat Pumps
Consumption .9 KWH/Ton
Average cost $ .15 KW
Supposition a clean heat exchanger will allow an additional 1-2 hours daily of non-mechanical cooling, when compared with a dirty one. (six day week)
Calculations
1 Hour/day savings
.9 KW x 300 tons x 1 hour x 130 days
The Advantages of Employing Custom Geogrid MeshHow to Customize Geogrid Mesh in 2024.9 x 300 x 130 = 35,100 KW
$ .15 x 35,100 = $ .00
2 Hour/day savings
FUYI BRUSH contains other products and information you need, so please check it out.
Featured content:How To Choose The Right Cutting Wheel For Your Angle ....9 x 300 x 2 hours x 130 = 70,200 KW
$ .15 x 70,200 KW = $ 10, 530.00
Average cost of cleaning $ .00
Before and After Heat Exchanger Cleaning Photos
Contact us today for Commercial and Industrial Water Treatment Solutions and for your HVAC Rehab needs.